Hi,
Here's the situation:
Two nodes share the same luns, one system is Sol 10 with SFCFSHA 6.0.
Some dg/vol created and configured to 6.0 cluster.
Install another node to RHEL 6 with SFHA 6.2, after then, all the disks became error in Sol 10 node.
Sol 10 + SFCFSHA 6.0 :
[root@sol25 /]#vxdisk -oalldgs list
DEVICE TYPE DISK GROUP STATUS
disk_0 auto:none - - online invalid
emc_clariion0_1 auto - - error
emc_clariion0_2 auto - - error
emc_clariion0_3 auto - - error
emc_clariion0_4 auto - - error
emc_clariion0_5 auto - - error
emc_clariion0_6 auto - - error
RHEL 6 + SFHA 6.2 :
[root@rhel26 ~]# vxdisk -oalldgs list
DEVICE TYPE DISK GROUP STATUS
emc_clariion0_1 auto:none - - online invalid
emc_clariion0_2 auto:none - - online invalid
emc_clariion0_3 auto:none - - online invalid
emc_clariion0_4 auto:none - - online invalid
emc_clariion0_5 auto:none - - online invalid
emc_clariion0_6 auto:none - - online invalid
How can I get the DGs back on Sol system ? Thanks in advance !